E019
myenergi Communication Fault with Hub / Linked Devices

Zappi displays E019, charging disabled, often when linked with myenergi hub or other myenergi devices

Advertisements

Possible Causes

Lost RF link to myenergi hub, Incorrect device pairing, RF interference, Faulty RF module on Zappi PCB

How to Fix / Troubleshooting

Safety first: Communication faults do not usually affect electrical safety but may affect smart features.

  • 1. Check hub status: Ensure the myenergi hub is powered, connected to the network, and showing normal status LEDs.
  • 2. Verify pairing: In the Zappi menu, check that the hub and any linked devices (eddi, harvi, etc.) are correctly paired and visible.
  • 3. Reduce interference: Move the hub closer to the Zappi or away from large metal objects and other RF sources (Wi‑Fi routers, microwaves).
  • 4. Re-pair devices: Remove and re-add the Zappi in the hub/app, following myenergi’s pairing procedure.
  • 5. Firmware update: Update firmware on both Zappi and hub to the latest versions.
  • 6. If RF module is faulty: Persistent E019 with good signal and correct pairing may indicate a failed RF module on the Zappi PCB, requiring board replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

RF Communication Module (on Main PCB)
Check Price on Amazon

We may earn a commission from links on this page.