E020
myenergi Generation / Export Limitation Fault

Zappi shows E020, charging inhibited, often when solar or battery integration is enabled

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect CT assignment for solar/battery, Misconfigured export limit, Firmware bug in export control, Faulty CT or CT input

How to Fix / Troubleshooting

Safety first: Export limitation affects compliance with grid regulations; ensure configuration is correct.

  • 1. Review CT configuration: In the Zappi menu, confirm that CTs are correctly assigned to Grid, Generation, and Battery as per your installation.
  • 2. Check export limit settings: Verify that any export limit values are set according to your DNO approval and not to unrealistic values.
  • 3. Inspect CT wiring: Ensure CT cables are intact and firmly connected to the correct CT inputs.
  • 4. Test in FAST mode: Temporarily disable ECO/ECO+ and export limiting, and test charging in FAST mode. If E020 disappears, the issue is in the export control configuration.
  • 5. Firmware update: Update to the latest firmware to resolve any known export control bugs.
  • 6. Replace CT or PCB if needed: If a known-good CT still causes E020, the CT input circuitry on the main PCB may be faulty.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Generation CT Clamp
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements