myenergi LCD / Display Module Failure

Zappi display is blank or unreadable but LEDs are on and charging still works

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed LCD backlight, Damaged display ribbon cable, Moisture ingress behind front panel, Faulty display driver on PCB

How to Fix / Troubleshooting

Safety first: Isolate power before removing the front cover.

  • 1. Power-cycle: Turn the Zappi off and on to see if the display recovers.
  • 2. Inspect display connection: With power off, remove the front cover and check the ribbon cable between the display and main PCB. Reseat it carefully.
  • 3. Check for moisture: Look for condensation or water marks behind the display window. Dry thoroughly if present and improve weather sealing if needed.
  • 4. Use app as workaround: If the myenergi app still communicates, you can temporarily control the charger while arranging repair.
  • 5. Replace display or PCB: If the LCD remains blank, the display module or its driver on the PCB may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Front Display Module
Check Price on Amazon

We may earn a commission from links on this page.