myenergi Short Circuit or High Inrush on Output

Zappi repeatedly trips the upstream MCB/RCBO as soon as charging starts

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted output wiring between Zappi and socket, Internal contactor short, Damaged Type 2 socket with internal short, Incorrectly wired supply polarity

How to Fix / Troubleshooting

Safety first: Do not repeatedly reset a tripping breaker; this indicates a fault.

  • 1. Visual inspection: With power off, inspect the output wiring and Type 2 socket for signs of damage, burning, or foreign objects.
  • 2. Insulation test: Have an electrician perform an insulation resistance test on the output circuit and cable.
  • 3. Disconnect cable/socket: Temporarily disconnect the tethered cable or socket from the Zappi output (with power off) and then power on. If the breaker no longer trips, the cable/socket is faulty.
  • 4. Check internal contactor: Inspect the contactor for welded contacts or internal shorts. Replace if suspect.
  • 5. Verify wiring: Confirm that line and neutral are correctly wired and not reversed or shorted.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Type 2 Socket Assembly