myenergi Measurement / CT Calibration Issue

Zappi’s myenergi app shows incorrect or zero power readings while charging appears normal

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

CT clamps installed on wrong conductors, CT orientation reversed, Loose CT connections at Zappi, Faulty CT clamp

How to Fix / Troubleshooting

Safety first: CTs are installed around live conductors; only qualified persons should adjust them inside consumer units.

  • 1. Check CT orientation: Ensure the arrow on each CT clamp points in the correct direction as per myenergi instructions.
  • 2. Verify CT placement: Confirm CTs are on the intended conductors (grid feed, solar feed, etc.), not on branch circuits.
  • 3. Inspect CT terminals: At the Zappi, ensure CT wires are firmly clamped in the correct CT input terminals.
  • 4. Reconfigure CTs: In the Zappi menu, reassign CT roles (Grid, Generation, etc.) to match the physical installation.
  • 5. Replace suspect CT: If one CT consistently reads zero or nonsense, swap it with another CT to see if the fault follows the clamp. Replace if faulty.