E13
Rolec Internal Energy Meter Communication Fault

Charger displays E13; app may show "meter error" or "MID meter communication fault" on metered Rolec units.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed internal kWh meter, Loose RS‑485 or pulse wiring between meter and control PCB, Incorrect meter address or protocol settings, Control PCB communication port failure

How to Fix / Troubleshooting

Safety first: The internal meter is connected to mains; isolate power before accessing.

  • Visual inspection: Locate the internal MID‑approved meter (if fitted). Check for display activity and any error icons on the meter itself.
  • Check communication wiring: Verify that the RS‑485 or pulse output wires are correctly terminated at both the meter and the Rolec control PCB. Tighten any loose terminals.
  • Verify configuration: In installer settings, confirm that the meter type, address, and baud rate match the installed meter’s specification.
  • Power‑cycle: Reboot the charger and observe whether the meter comes online and E13 clears.
  • Replace meter or PCB: If the meter display is blank or shows its own error, replace the meter. If the meter appears healthy but communication still fails, the control PCB communication interface may be faulty.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Internal MID energy meter
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements