E17
Schneider Electric Dynamic Load Management (DLM) / External Meter Communication Fault

Charger displays E17 or load management error; unit may limit current to very low values or block charging.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Lost communication with Schneider external energy meter, Broken RS-485 or Modbus cable, Incorrect DLM configuration, Faulty DLM controller module

How to Fix / Troubleshooting

Safety first: De-energize the charger and any associated external meters before working on communication wiring.

  • Check external meter status: Verify that the Schneider energy meter used for load management is powered and displaying values.
  • Inspect communication wiring: Follow the RS-485/Modbus cable from the EVlink charger to the meter. Ensure A/B lines are correctly connected, polarity is correct, and shield is properly grounded as per Schneider guidelines.
  • Verify DLM settings: Using the EVlink configuration interface, confirm that load management is enabled only if an external meter is present and correctly addressed.
  • Test without DLM: Temporarily disable load management (if allowed) to see if charging resumes normally. This helps isolate the issue to the DLM system.
  • Technician diagnosis: If E17 persists, a Schneider Electric–qualified technician should test the communication bus and replace the DLM controller or external meter if defective.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Schneider EVlink DLM controller / external energy meter