E009
Siemens Internal Communication Bus Fault

Display shows E009; charger powers up but cannot start a session and may show ‘communication error’.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose ribbon cable between display module and main control board, Faulty communication interface (e.g., RS-485/CAN) on control board, Corrupted firmware on HMI/display module, Electrical noise interfering with internal bus

How to Fix / Troubleshooting

Safety first: Isolate power before opening the housing or touching internal connectors.

  • Power cycle: Turn off the breaker for 2 minutes, then restore power and check if E009 clears.
  • Inspect internal connectors: With power OFF, remove the front cover and check ribbon cables and plug-in connectors between the display/HMI module and the main control board. Reseat them firmly.
  • Check for moisture or corrosion: Look for signs of condensation or corrosion on connectors and PCBs. If present, the unit may have lost its IP rating and require professional refurbishment.
  • Firmware reload (if supported): Use Siemens service tools to reload firmware to the HMI and main board, following official procedures.

Persistent E009 after reseating connectors and firmware checks indicates a likely hardware failure of the HMI or main control board; contact Siemens service.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Display / HMI Module or Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements