E013
Siemens Isolation Monitoring Fault (for IT/isolated systems)

Charger shows E013; charging is disabled and an internal fault LED may be lit.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Insulation fault between live conductors and earth, Moisture ingress inside charger enclosure, Faulty insulation monitoring device (IMD) on control board, Incorrect earthing or bonding configuration

How to Fix / Troubleshooting

Safety first: An insulation fault can lead to electric shock. Do not continue using the charger until the cause is identified.

  • Inspect enclosure: Check for cracks, open cable glands, or missing seals that could allow water ingress. Dry the interior thoroughly if moisture is present.
  • Check cable condition: Examine the tethered cable for cuts or crushed sections that could compromise insulation.
  • Insulation test (professional): A qualified electrician can perform insulation resistance tests between live conductors and earth to locate faults.
  • Verify earthing: Ensure the charger is connected to a proper earth system as specified by Siemens and local codes.

If no external insulation fault is found and E013 persists, the internal IMD or isolation monitoring circuit may be defective and requires Siemens service.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Isolation Monitoring Circuit / IMD Module
Check Price on Amazon