E014
Siemens Output Relay / Contactor Control Fault

Siemens wallbox shows E014; unit appears dead to the vehicle but display or LEDs may still be on.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed relay driver on main control board, Broken coil wire on main contactor, Loose control wiring between board and contactor, Control board detecting inconsistent contactor feedback

How to Fix / Troubleshooting

Safety first: Isolate power before inspecting internal components.

  • Listen for contactor: When starting a charge, listen for a distinct click from the main contactor. No click suggests a control or coil issue.
  • Inspect control wiring: With power OFF, check the small-gauge wires from the main control board to the contactor coil and feedback contacts. Ensure terminals are tight and not corroded.
  • Coil resistance test: A technician can measure the contactor coil resistance with a multimeter; an open circuit indicates a failed coil.
  • Board output check: Using appropriate test equipment, verify that the control board is providing the correct voltage to the coil when a session is commanded.

If the contactor and wiring are good but E014 persists, the relay driver circuitry on the main control board is likely faulty and the board should be replaced.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Power Contactor and Control Wiring
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements