Charger shows E017; RFID cards or user authentication fail and charging is blocked.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Authentication components are low voltage; still isolate power before opening the housing.
- Test multiple cards: Try several known-good, authorized RFID cards or tags. If none are recognized, suspect the reader or configuration.
- Check reader window: Clean the RFID reader area on the front panel; dirt or stickers can reduce read range.
- Configuration check: Use the Siemens configuration tool to verify that RFID mode is enabled and that cards are correctly enrolled.
- Inspect wiring: With power OFF, reseat the connector from the RFID reader module to the main control board.
If E017 persists and no cards are recognized after configuration and wiring checks, the RFID reader module or the authentication logic on the control board may require replacement.