E019
Siemens Real-Time Clock / Time Synchronization Fault

Charger shows E019; scheduled charging or dynamic load management does not function correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed real-time clock (RTC) chip on control board, Depleted RTC backup battery, Loss of NTP time sync due to network issues, Corrupted time settings in configuration

How to Fix / Troubleshooting

Safety first: Time settings can be adjusted via user interface; opening the unit for RTC battery replacement should be done with power isolated.

  • Check time settings: Using the local display or app, verify that date, time, and time zone are correct. Correct them if necessary.
  • NTP sync: Ensure the charger has internet access and NTP synchronization enabled if supported. Confirm DNS and gateway settings.
  • Disable schedules: Temporarily disable scheduled charging or load management to allow immediate charging while troubleshooting.
  • RTC battery (advanced): If the time resets after every power cycle, the RTC backup battery on the control board may be depleted and require replacement by a technician.

If E019 persists after correcting time and network settings, the RTC hardware on the control board may be defective.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Real-Time Clock Circuit / Backup Battery
Check Price on Amazon