Siemens
RFID Reader Hardware Failure
RFID card reader area on Siemens charger is unresponsive; no beep or LED change when card is presented, but charging still works in plug-and-charge mode.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed RFID antenna or reader PCB, Disconnected ribbon cable to RFID module, Physical damage to front panel around reader, Firmware configuration disabling RFID unintentionally
How to Fix / Troubleshooting
Safety first: Isolate power before opening the front panel.
- Check configuration: Verify in the Siemens app or web interface that RFID authentication is enabled.
- Test multiple cards: Try several known-good RFID cards to rule out card failure.
- Inspect connections: With power OFF, remove the front cover and reseat the connector between the RFID reader and main control board.
- Physical inspection: Look for cracks or impact damage around the reader area that could have broken the antenna.
If the reader remains unresponsive after these checks, replace the RFID reader module according to Siemens service instructions.