E09
Sun Country Highway
Stuck Relay / Contactor Feedback Error
Display shows E09; charger may start then immediately stop, or refuse to start at all.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty contactor auxiliary feedback contacts, Miswired feedback circuit, Control board feedback input failure, Welded main contacts with incorrect feedback state
How to Fix / Troubleshooting
Safety first: This involves high-voltage switching. Turn off power and confirm de‑energized before opening the unit.
- Check wiring to auxiliary contacts: Locate the auxiliary (feedback) contacts on the main contactor and ensure their wires are secure and match the wiring diagram.
- Inspect for mechanical damage: If the contactor shows signs of overheating or mechanical failure, replace it with the Sun Country Highway-specified part.
- Continuity test (advanced): A technician can test the auxiliary contacts with a multimeter to ensure they change state when the contactor coil is energized. If they do not, the contactor must be replaced.
- Control board diagnosis: If the auxiliary contacts function correctly but E09 persists, the feedback input on the control board may be defective and require board replacement.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Main Power Contactor with Auxiliary Contacts
Check Price on Amazon