Vestel
Fan Control / Temperature Sensing Anomaly
Vestel EV charger’s internal fan runs constantly even when not charging, and the unit is noisy.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck temperature sensor reading high, Fan control output on main board stuck on, Firmware configuration forcing continuous cooling, Shorted fan control transistor
How to Fix / Troubleshooting
Safety first: Isolate power before accessing internal components.
- 1. Check temperature reading: In the service interface, view the reported internal temperature. If it is unrealistically high, suspect a sensor fault.
- 2. Inspect sensor connection: Locate the NTC temperature sensor and ensure its connector is secure and wires are intact.
- 3. Firmware settings: Verify that no diagnostic or forced-cooling mode is enabled in the configuration.
- 4. Replace sensor: If the sensor reading is incorrect and wiring is good, replace the NTC sensor.
- 5. Board repair: If the sensor reads correctly but the fan remains on, the fan control transistor or driver on the main board may be shorted; replace the main control or power board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Internal Temperature Sensor (NTC)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements