Vestel Fan Control / Temperature Sensing Anomaly

Vestel EV charger’s internal fan runs constantly even when not charging, and the unit is noisy.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck temperature sensor reading high, Fan control output on main board stuck on, Firmware configuration forcing continuous cooling, Shorted fan control transistor

How to Fix / Troubleshooting

Safety first: Isolate power before accessing internal components.

  • 1. Check temperature reading: In the service interface, view the reported internal temperature. If it is unrealistically high, suspect a sensor fault.
  • 2. Inspect sensor connection: Locate the NTC temperature sensor and ensure its connector is secure and wires are intact.
  • 3. Firmware settings: Verify that no diagnostic or forced-cooling mode is enabled in the configuration.
  • 4. Replace sensor: If the sensor reading is incorrect and wiring is good, replace the NTC sensor.
  • 5. Board repair: If the sensor reads correctly but the fan remains on, the fan control transistor or driver on the main board may be shorted; replace the main control or power board.