Error 15
Wallbox
Dynamic Load Management / Power Sharing Communication Fault
Wallbox indicates 'Error 15'; charging is disabled and may reference 'load management' or 'power sharing' issues.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Broken RS‑485 or CAN bus wiring between Wallbox units, Incorrect master/slave configuration, Faulty external power meter, EMI on load management bus
How to Fix / Troubleshooting
Safety first: Turn off power to all interconnected chargers before modifying bus wiring.
- Check topology: Verify that the Wallbox units are wired according to the load management diagram (daisy chain, correct polarity on A/B lines, proper termination resistors).
- Verify roles: In the app or installer interface, confirm that one unit is configured as master and others as slaves, and that group IDs match.
- Inspect bus wiring: With power off, check the integrity of the twisted pair used for RS‑485/CAN. Look for loose terminals, reversed polarity, or damaged cable.
- Test without external meter: Temporarily disconnect the external power meter (if used) and configure the system for standalone operation. If Error 15 clears, the meter or its wiring is faulty.
- Module replacement: If wiring and configuration are correct but communication still fails, replace the communication interface module or main board on the affected unit.
Load management faults can lead to overloading the supply if bypassed. Ensure the system is correctly repaired before enabling full‑power charging.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
RS‑485 / CAN Communication Interface
Check Price on Amazon
We may earn a commission from links on this page.