Error 18
Wallbox
External Meter / CT Communication or Measurement Fault
Wallbox shows 'Error 18'; charging is disabled and may be associated with external energy meter or CTs used for dynamic load management.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect wiring of external CT clamps, Reversed CT orientation, Faulty Modbus/RS‑485 connection to external meter, Incompatible meter model
How to Fix / Troubleshooting
Safety first: Turn off power to the Wallbox and external meter before adjusting CTs or wiring.
- Verify meter model: Confirm that the external meter is a Wallbox‑approved model and is configured for the correct protocol and baud rate.
- Check CT orientation: Ensure that CT clamps are installed on the correct conductors and oriented according to the arrows (toward the load or source as specified). Incorrect orientation can cause negative or zero readings.
- Inspect RS‑485 wiring: Confirm that A/B lines are correctly connected between the meter and Wallbox, with proper termination resistors if required.
- Check meter address: In the meter settings, verify that the Modbus address matches the value configured in the Wallbox app or installer menu.
- Test without meter: Temporarily disable dynamic load management in the Wallbox configuration and see if Error 18 clears. If so, the issue is with the meter or CTs.
Correct wiring and configuration usually resolve this error. If not, replace the external meter or consult Wallbox support.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
External Energy Meter / CT Set
Check Price on Amazon
We may earn a commission from links on this page.