E20
Walli
External Current Transformer (CT) / Load Management Fault
Charger shows E20; app indicates 'Load management error' or 'External CT fault' on systems with dynamic load balancing.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Disconnected or reversed external CTs on main supply, Damaged CT cable to Walli load controller, Incorrect CT ratio or configuration, Faulty Walli load management module
How to Fix / Troubleshooting
Safety first: CTs are installed on live mains; only qualified electricians should adjust them.
Steps:
- Visual inspection: Check that all external CTs are securely clamped around the correct conductors and oriented according to the arrows.
- Check CT wiring: Trace the CT cables back to the Walli load management input terminals. Ensure no cuts or pinches and that terminals are tight.
- Configuration: In the Walli installer settings, verify CT ratio, phase assignment, and load management mode.
- Test without load management: Temporarily disable dynamic load balancing (if allowed) to see if the charger operates normally. If so, the issue is isolated to the CT/load management system.
- Replace CTs or module: If wiring and configuration are correct but E20 persists, replace the external CT set or the Walli load management module as per service guidance.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Walli load management module
Check Price on Amazon