AEG Partial Loss of Refrigerant / Low Cooling Capacity

Freezer runs but does not reach set temperature, only slightly cool

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Refrigerant leak in evaporator or pipework, Partially blocked capillary tube, Weak compressor, Condenser heavily clogged reducing heat rejection

How to Fix / Troubleshooting

Safety: Do not attempt to cut or open any refrigerant lines. Unplug before cleaning or inspection.

Steps:

  • 1. Check condenser: Clean dust and lint from the condenser coils and ensure good airflow around the unit.
  • 2. Door and gasket: Verify the door seals tightly all around. Replace damaged gaskets to prevent warm air ingress.
  • 3. Frost pattern: With the rear internal panel removed (if accessible), observe the evaporator after 15–20 minutes of running. A healthy system shows even frost across most of the coil. Frost only at the inlet or a small section suggests low refrigerant or restriction.
  • 4. Load and usage: Avoid overloading and ensure air can circulate between baskets.

If the frost pattern is abnormal or cooling remains weak despite clean condenser and good seals, a sealed system repair (leak detection, recharging, or compressor replacement) is required and must be performed by a licensed refrigeration technician.