AL
Amana General Alarm Condition (Temperature or Door)

Control panel shows AL and an audible alarm sounds, indicating an abnormal condition.

Advertisements

Possible Causes

Door left open, High temperature condition, Faulty door switch, Failed thermistor reporting incorrect temperature

How to Fix / Troubleshooting

Safety: No internal work is required for basic checks.

Steps:

  • Check door: Ensure the door is fully closed and not obstructed. Verify the gasket is sealing all around.
  • Silence alarm: Press the alarm reset button. If the alarm returns, investigate further.
  • Check temperature: Use a freezer thermometer to confirm actual temperature. If above 10°F (-12°C), there is a cooling issue.
  • Door switch and sensor: If the alarm persists with normal temperature and closed door, test the door switch and cabinet thermistor and replace if faulty.

Note: Persistent alarms with normal operation may indicate a failing control board.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.