H1
Amana
High Temperature Alarm Condition
Display shows H1 or HI and the freezer interior is too warm; high temperature alarm may sound.
Advertisements
Possible Causes
Door left open or frequently opened, Failed door gasket causing air leaks, Defective thermistor reading too warm, Sealed system cooling issue
How to Fix / Troubleshooting
Safety: No internal electrical work is required for basic checks, but unplug the unit before removing panels.
Immediate actions:
- Verify door closure: Ensure the door is fully closed and not blocked by food items. Listen for the latch engaging.
- Check gasket: Inspect the door gasket for tears, gaps, or debris. Clean with warm soapy water and dry. Replace if damaged or not sealing.
- Allow recovery time: If the door was left open, close it and allow 12–24 hours for the temperature to return to normal. Avoid frequent door openings.
- Check loading: Do not overpack against the rear wall or air vents; maintain airflow.
- Sensor and cooling checks: If H1 persists with a closed door, test the cabinet thermistor and verify the compressor and fans are running. Replace a faulty thermistor or contact a technician if the sealed system is not cooling.
Food safety: Discard perishable items that have been above 0°F (-18°C) for extended periods.