L1
Amana Low Temperature / Overcooling Condition

Amana freezer display shows L1 or LO and the interior temperature is extremely cold, sometimes causing items to freeze harder than normal or frost on packages.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck or shorted thermistor reading too warm, Control board not cycling compressor off, Temperature set too low, Failed control relay welded closed

How to Fix / Troubleshooting

Safety: Unplug the freezer before accessing controls or sensors.

Steps:

  • Check temperature setting: Ensure the setpoint is not at the coldest setting. Adjust to a mid-range setting and monitor for 24 hours.
  • Inspect thermistor: Test the cabinet thermistor for proper resistance at known temperatures. Replace if out of specification.
  • Observe compressor operation: If the compressor runs nearly constantly even after adjusting the setpoint, the control board may not be cycling it off.
  • Control board replacement: If the thermistor is good and the compressor never shuts off, replace the main control board, as the compressor relay may be stuck closed.

Note: Overcooling can increase energy use and cause excessive frost; correct promptly.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Electronic Control Board
Check Price on Amazon