Amana
Interior Light Circuit Failure
Interior light does not come on when the door is opened, but the freezer still cools.
Advertisements
Possible Causes
Burned-out light bulb or LED module, Failed door switch, Loose light socket connection, Wiring issue in light circuit
How to Fix / Troubleshooting
Safety: Unplug the freezer before replacing bulbs or working on wiring.
Steps:
- Replace bulb: If equipped with an incandescent bulb, remove the lens cover and replace the bulb with the correct wattage and type.
- Test door switch: Press the door switch by hand; if the light flickers or never comes on, test the switch for continuity and replace if faulty.
- Check connections: Inspect the light socket and wiring for loose or burnt connections. Repair as needed.
- LED modules: On LED-equipped models, replace the LED light module if it has failed.
Advertisements
Repair Difficulty
Very Easy
1/5