E14
Amica Compressor Relay / Output Error

E14 displayed, freezer may not cool properly; compressor may not start even though display is on.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor relay on main PCB, Burnt relay contacts due to high current, Cracked solder joints on relay pins, Control board not sending start signal to compressor

How to Fix / Troubleshooting

Safety: Unplug the freezer before accessing the main control board. High voltages are present.

Diagnosis:

  • 1. Listen for compressor: When powered, if you never hear the compressor start (no humming or vibration) but the display works, suspect the relay or control board.
  • 2. Access main PCB: Remove the rear lower panel and locate the control board. Identify the compressor relay (often a small rectangular component near the compressor output terminals).
  • 3. Visual inspection: Look for burn marks, cracked casing, or darkened PCB around the relay. Check for cracked solder joints on the relay pins.
  • 4. Re-solder (advanced): If you are experienced with soldering, you may reflow cracked joints. Otherwise, replace the entire board.
  • 5. Replace main PCB: If the relay is clearly damaged or E14 persists, replace the "Amica Main Control Board" with the correct part for your model.

Warning: Do not attempt to bypass the relay or hard-wire the compressor; this is dangerous and can cause fire or compressor damage.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements