E16
Amica Door Sensor Circuit Short / Open

E16 displayed, freezer may not recognize door open/close state; interior light may stay on constantly.

Advertisements

Possible Causes

Shorted door switch wiring, Broken harness in door hinge area, Failed door switch contacts, Corroded connector at control board

How to Fix / Troubleshooting

Safety: Unplug the freezer before working on wiring.

Procedure:

  • 1. Observe behavior: Check if the interior light stays on with the door closed or never comes on. This helps determine if the circuit is stuck open or closed.
  • 2. Inspect hinge area: On some Amica models, door switch wiring passes near the hinge. Look for pinched or broken wires.
  • 3. Test door switch: Remove the switch and test continuity with a multimeter while actuating it. Replace if readings do not change.
  • 4. Check connector at PCB: Trace the switch wires to the main board and ensure the connector is clean and firmly seated.
  • 5. Replace faulty parts: Install a new "Amica Door Switch" or repair the harness as needed. Clear the error by unplugging for several minutes.

Note: A stuck-on light can heat the freezer interior and raise temperature.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon