E8
Amica Defrost Sensor Calibration / Out-of-Range Error

E8 displayed, freezer may not defrost properly or may show irregular frost patterns on the evaporator.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defrost sensor reading out of expected range, Sensor not properly clipped to evaporator, Incorrect replacement sensor installed, Wiring resistance added by poor connections

How to Fix / Troubleshooting

Safety: Disconnect mains power before accessing internal components.

What to do:

  • 1. Verify recent repairs: If a sensor was recently replaced, confirm that the correct Amica part number was used and that it is installed in the original position on the evaporator.
  • 2. Access evaporator area: Remove the internal rear panel to expose the evaporator and defrost sensor. Ensure the sensor is firmly clipped to the coil and not hanging loose.
  • 3. Check connections: Inspect the sensor connector for loose pins or poor crimping. Reseat the plug and ensure no extra splices or extensions have been added that could alter resistance.
  • 4. Compare resistance: Measure sensor resistance at a known temperature (e.g., room temperature or in ice water) and compare with manufacturer data if available. Replace with a genuine "Amica Defrost NTC Sensor" if readings are out of range.
  • 5. Clear error: After correcting the issue, unplug the freezer for several minutes to reset the control, then restore power and monitor for recurrence.

Note: Persistent E8 with correct sensors and wiring may indicate a faulty main control board.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Defrost NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements