Amica
Door Gasket Failure or Door Misalignment
Freezer door not sealing properly, visible gaps or condensation around the door frame.
Advertisements
Possible Causes
Deformed or torn door gasket, Door hinges loose or bent, Cabinet warped due to improper leveling, Magnetic strip in gasket weakened
How to Fix / Troubleshooting
Safety: Unplug the freezer before adjusting hinges to avoid accidental fan or light operation.
Steps:
- 1. Inspect gasket: Look for tears, hardened sections, or areas not contacting the cabinet. Clean the gasket with warm soapy water and dry.
- 2. Warm and reshape: Use a hair dryer on low to gently warm deformed areas and pull them into shape. Allow to cool while holding in position.
- 3. Adjust hinges: Tighten hinge screws and adjust the door so it is square with the cabinet and closes evenly.
- 4. Replace gasket: If damage is severe, remove the old gasket (usually pressed into a channel) and fit a new "Amica Freezer Door Gasket" for your model.
Tip: After replacement, close the door and check for uniform contact all around using the paper test.
Advertisements
Repair Difficulty
Easy