Ariston
Air Circulation / Evaporator Fan Problem
Freezer interior warm at top but cold at bottom; uneven cooling between shelves or drawers.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Evaporator fan not running, Ice blocking air ducts, Overpacked shelves blocking vents, Fan motor wiring fault
How to Fix / Troubleshooting
Safety first: Unplug the freezer before removing internal panels.
- Check loading: Ensure food packages are not blocking the rear or side air vents. Leave space for air to circulate.
- Listen for fan: With the door closed and the unit running, listen for the evaporator fan. If silent, open the door and press the door switch to see if the fan starts.
- Inspect for ice: Remove the rear internal panel and check for ice buildup around the fan and air channels. Manually defrost if necessary.
- Replace fan if needed: If the fan motor is seized or noisy, replace it with an Ariston-compatible evaporator fan motor.
When to call a technician: If the fan receives power but does not run, or if air ducts are damaged, professional repair is recommended.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator Fan Motor
Check Price on Amazon