Ariston
Insufficient Cooling / Poor Performance
Freezer runs but does not reach set temperature; food is soft or slowly thawing.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty condenser coils, Condenser fan not running, Door gasket leaking warm air, Partial refrigerant loss
How to Fix / Troubleshooting
Safety first: Unplug the freezer before cleaning coils or touching the compressor area.
- Clean condenser: Pull the Ariston freezer away from the wall and vacuum dust from the condenser coils and compressor area.
- Check condenser fan: On no-frost models, verify the fan near the condenser runs when the compressor is on. Replace the fan motor if it does not run.
- Inspect door gasket: Close the door on a sheet of paper and gently pull. If it slides out easily in multiple spots, the gasket may be worn and should be replaced.
- Reduce door openings: Avoid frequent or prolonged door openings while the freezer is trying to recover temperature.
When to call a technician: If performance remains poor after cleaning and gasket checks, a sealed-system issue such as a refrigerant leak may be present and requires professional service.
Advertisements
Repair Difficulty
Medium
3/5