Freezer not cooling at all; interior is warm; compressor and fans are not running; display may be lit.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Disconnect power before opening any control covers. Risk of electric shock is present.
- Confirm power: Test the wall outlet with another appliance. Check the circuit breaker.
- Check for error codes: If the display shows an alarm code, follow the specific code procedure. If no code, continue.
- Inspect control board: Remove the control cover and look for burnt components, loose connectors, or a blown internal fuse (if fitted). Replace the fuse only with the same rating and investigate the cause of failure.
- Check wiring harnesses: Ensure connectors to the compressor, fans, and sensors are firmly seated.
If the board appears damaged or there is no output to the compressor and fans despite correct input power, replace the main control board or contact a technician for further diagnosis.
Repair Difficulty
Required Part
We may earn a commission from links on this page.