Asko No Cooling – Control or Power Circuit Failure

Freezer not cooling at all; interior is warm; compressor and fans are not running; display may be lit.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed main control board, Faulty thermostat or temperature sensor, Open thermal fuse, Loose power wiring inside control compartment

How to Fix / Troubleshooting

Safety first: Disconnect power before opening any control covers. Risk of electric shock is present.

  • Confirm power: Test the wall outlet with another appliance. Check the circuit breaker.
  • Check for error codes: If the display shows an alarm code, follow the specific code procedure. If no code, continue.
  • Inspect control board: Remove the control cover and look for burnt components, loose connectors, or a blown internal fuse (if fitted). Replace the fuse only with the same rating and investigate the cause of failure.
  • Check wiring harnesses: Ensure connectors to the compressor, fans, and sensors are firmly seated.

If the board appears damaged or there is no output to the compressor and fans despite correct input power, replace the main control board or contact a technician for further diagnosis.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon