E5
Avanti Compressor Overload / High Current Protection

Avanti digital freezer shows E5 and may stop cooling or cycle off prematurely.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor start relay or PTC, Weak or locked compressor, Low line voltage or unstable power supply, Faulty main control board compressor driver

How to Fix / Troubleshooting

Safety: Unplug the freezer before accessing the compressor compartment. The compressor and nearby components can be hot.

Steps:

  • Check power supply: Ensure the freezer is plugged directly into a properly grounded wall outlet (no extension cords). Use a different outlet if possible. If lights dim when the compressor tries to start, there may be a household wiring issue.
  • Access compressor area: Remove the rear lower cover to expose the compressor, start relay/PTC, and overload protector.
  • Inspect start device: Remove the start relay/PTC from the compressor terminals. Shake it gently; if it rattles or shows burn marks, it is likely defective and should be replaced.
  • Test compressor windings: With the unit unplugged, remove all wires from the compressor terminals and measure resistance between each pair (C-R, C-S, R-S). You should see finite resistance values and no open circuits. Also check each terminal to ground (compressor shell); there should be no continuity. If windings are shorted to ground or open, the compressor is bad.
  • Replace start relay/overload: If the compressor tests good, install a new OEM start relay/overload assembly designed for your Avanti model.
  • Control board: If the compressor never receives power (verify with a meter) despite a call for cooling, the main control board may be faulty and require replacement.

Note: Compressor replacement and sealed system work must be done by an EPA-certified technician.