Avanti Interior Light Failure

Freezer interior light does not turn on when door is opened, but unit cools normally.

Advertisements

Possible Causes

Burned-out LED module or bulb, Faulty door switch, Loose wiring to light assembly, Failed light driver circuit on control board

How to Fix / Troubleshooting

Safety: Unplug the freezer before replacing bulbs or working on wiring.

Steps:

  • Check bulb/module: On models with replaceable bulbs, remove and visually inspect the bulb. Replace with the correct type if filament is broken or LED is dark.
  • Test door switch: Press the door switch by hand; if the light flickers or never comes on, test the switch for continuity with a multimeter. Replace if faulty.
  • Inspect wiring: Ensure the light assembly connector is secure and wires are intact.
  • Control board: If the bulb and switch are good but no voltage is present at the light socket, the control board's light circuit may be defective and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon