Possible Causes
Burned-out LED module or bulb, Faulty door switch, Loose wiring to light assembly, Failed light driver circuit on control board
How to Fix / Troubleshooting
Safety: Unplug the freezer before replacing bulbs or working on wiring.
Steps:
- Check bulb/module: On models with replaceable bulbs, remove and visually inspect the bulb. Replace with the correct type if filament is broken or LED is dark.
- Test door switch: Press the door switch by hand; if the light flickers or never comes on, test the switch for continuity with a multimeter. Replace if faulty.
- Inspect wiring: Ensure the light assembly connector is secure and wires are intact.
- Control board: If the bulb and switch are good but no voltage is present at the light socket, the control board's light circuit may be defective and require replacement.