Avanti Continuous Run / Control Fault

Freezer runs continuously without shutting off, but interior is at or below set temperature.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Thermostat contacts welded closed, Temperature sensor reading too warm, Control board relay stuck on, Door gasket leaking causing constant heat gain

How to Fix / Troubleshooting

Safety: Unplug the freezer before testing controls.

Steps:

  • Verify actual temperature: Use an accurate freezer thermometer to confirm interior temperature. If it is much colder than setpoint, suspect a control issue.
  • Inspect gasket: Check for frost near the door and test gasket seal. Replace if leaking.
  • Test thermostat: On mechanical models, turn the thermostat to OFF. If the compressor keeps running, the thermostat is stuck and must be replaced.
  • Sensor/control board: On digital models, test the cabinet sensor and replace if out of spec. If sensor is good, replace the main control board if it continues to power the compressor constantly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Thermostat / Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements