Bauknecht Compressor Start Failure

Freezer interior light works but compressor never starts, faint click heard periodically

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective PTC start relay, Open overload protector, Seized compressor, Loose wiring at compressor terminals

How to Fix / Troubleshooting

Safety: Unplug the freezer before accessing the compressor area.

  • Access compressor: Remove the rear lower panel to expose the compressor and electrical box.
  • Inspect start components: Remove the start relay and overload. Check for rattling pieces inside the relay or burn marks.
  • Test compressor windings: With the start device removed, measure resistance between the three compressor pins. All readings should be finite and not shorted to ground. If windings are open or shorted, the compressor is faulty.
  • Replace start device: If the compressor tests OK, install a new Bauknecht-compatible start relay and overload.
  • Professional service: If the compressor is seized or electrically faulty, it must be replaced by a certified refrigeration technician.