Bauknecht
Thermostat / Temperature Control Fault
Freezer overcooling, temperature much lower than setpoint, items excessively frosted or rock-hard
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck relay on main PCB, Shorted temperature sensor causing low reading, Faulty control algorithm in PCB, Incorrect sensor placement touching evaporator
How to Fix / Troubleshooting
Safety: Unplug the freezer before accessing sensors or control boards.
- Verify setpoint: Confirm the temperature setting is not at the coldest level or in Super Freeze mode.
- Check sensor placement: Ensure the freezer NTC sensor is correctly clipped in its holder and not directly touching the evaporator coil, which can cause falsely low readings.
- Compare with thermometer: Place a separate thermometer inside to confirm actual temperature.
- Test sensor: Measure the NTC resistance and compare to spec. Replace if out of range.
- Control board: If the sensor is correct but the compressor never cycles off, the main PCB relay may be stuck closed. Board replacement is required and should be done by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Freezer Temperature NTC Sensor
Check Price on Amazon