Bauknecht Frozen or Misaligned Defrost Drain

Ice buildup on the bottom of the freezer compartment

Advertisements

Possible Causes

Partially blocked drain hole, Drain tube not seated in pan, Excessive warm air entering due to door seal leak, Defrost water refreezing before draining

How to Fix / Troubleshooting

Safety: Unplug the freezer and protect the floor from water.

  • Manual defrost: Remove all food and drawers. Leave the door open until all ice melts, using towels to absorb water.
  • Clear drain: After ice removal, locate and clear the drain hole with warm water and a flexible cleaner as described in the drain blockage entry.
  • Check drain pan alignment: Ensure the drain tube correctly empties into the pan above the compressor.
  • Inspect door gasket: Replace if damaged to reduce warm, moist air entering and overloading the defrost system.
Advertisements

Repair Difficulty

Easy 2/5
Advertisements