dF
Belling Defrost Mode Indication / Stuck in Defrost

Display shows dF or DEF and the freezer may pause cooling while in defrost mode.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Control stuck in defrost cycle, Faulty defrost sensor feedback, Main PCB logic fault, Defrost relay stuck closed

How to Fix / Troubleshooting

Safety: Unplug the freezer before accessing internal components.

Checks:

  • 1. Wait cycle out: Some Belling models briefly show dF during normal automatic defrost. If it clears within 30–60 minutes and cooling resumes, no fault is present.
  • 2. If stuck: If dF remains for several hours and the freezer warms, unplug the unit for 10–15 minutes to reset the control.
  • 3. Sensor check: Inspect and test the defrost sensor/thermostat as described in the E4 scenario. Incorrect feedback can keep the unit in defrost.
  • 4. PCB/relay: If the heater remains powered or the compressor is not commanded on after reset, the defrost relay or PCB logic may be faulty. Replace the main control PCB.

Warning: Do not bypass defrost safety devices or run the heater continuously.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.