Belling
Overcooling – Thermostat Stuck Closed
Freezer over-freezing; temperature much lower than set, with excessive frost on food and walls.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Mechanical thermostat contacts welded closed, Shorted temperature sensor causing false warm reading, Main PCB output relay stuck on, Fast-freeze mode permanently engaged
How to Fix / Troubleshooting
Safety: Disconnect power before accessing the control housing.
Steps:
- 1. Check settings: Ensure fast-freeze is off and the temperature is set to around -18°C.
- 2. Mechanical thermostat: If fitted, remove the control knob and housing, then test the thermostat for switching. Replace if it remains closed regardless of temperature.
- 3. Electronic sensor: Test the cabinet NTC sensor for correct resistance. Replace if shorted or out of range.
- 4. PCB relay: If the compressor continues to run even when the control should be off, the relay may be stuck. Replace the main control PCB.
Advertisements
Repair Difficulty
Medium
3/5