Belling
Poor Cooling – Long Run Time
Freezer runs but does not get cold enough; temperature stays above -10°C even after many hours.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty condenser coil reducing heat dissipation, Failed condenser fan motor (if fitted), Low refrigerant charge due to leak, Partially blocked capillary tube or filter-drier
How to Fix / Troubleshooting
Safety: Unplug the freezer before cleaning or accessing the rear compartment.
Steps:
- 1. Check door seal: Ensure the door gasket seals all around and that the door is not frequently opened.
- 2. Clean condenser: Pull the freezer away from the wall. Brush or vacuum dust from the condenser coil at the back or underneath. Ensure at least a few centimetres of clearance for airflow.
- 3. Condenser fan: If your Belling model has a condenser fan, confirm it runs when the compressor is on. Replace the condenser fan motor if it is not running and power is present.
- 4. Frost pattern: If accessible, remove the internal rear panel and inspect the evaporator. A small frost patch only near the inlet suggests a refrigerant issue or blockage, which requires a refrigeration engineer.
- 5. Load and environment: Avoid overloading the freezer and keep it away from heat sources.
Note: Refrigerant work must be done by a certified technician; do not attempt to open the sealed system yourself.