Bomann
Interior Light Circuit Failure
Freezer interior light does not work when door is opened, but cooling is normal.
Advertisements
Possible Causes
Burned-out LED module or bulb, Faulty door switch, Loose light connector, Failed light driver on control board
How to Fix / Troubleshooting
Safety: Unplug the freezer before changing bulbs or LED modules.
Steps:
- 1. Check door switch: Press the switch manually and see if the light flickers. If not, test the switch for continuity and replace if faulty.
- 2. Replace bulb/LED: Remove the light cover inside the cabinet. Replace the bulb or LED module with a Bomann-compatible part of the same rating.
- 3. Inspect wiring: Ensure the light harness is firmly connected and not damaged.
- 4. Control board: If the switch and light module are good but no voltage is supplied, the control board light circuit may be defective and require replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Interior LED Light Module
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements