Possible Causes

Burned-out LED module or bulb, Faulty door switch, Loose light connector, Failed light driver on control board

How to Fix / Troubleshooting

Safety: Unplug the freezer before changing bulbs or LED modules.

Steps:

  • 1. Check door switch: Press the switch manually and see if the light flickers. If not, test the switch for continuity and replace if faulty.
  • 2. Replace bulb/LED: Remove the light cover inside the cabinet. Replace the bulb or LED module with a Bomann-compatible part of the same rating.
  • 3. Inspect wiring: Ensure the light harness is firmly connected and not damaged.
  • 4. Control board: If the switch and light module are good but no voltage is supplied, the control board light circuit may be defective and require replacement.