AL04
Brandt
Door Open Alarm / Door Switch Fault
Freezer displays AL04; unit may not start cooling or may shut down unexpectedly
Advertisements
Possible Causes
Defective door switch or reed sensor, Misaligned door magnet, Broken or loose door switch wiring, Faulty main control board input
How to Fix / Troubleshooting
Safety first: Disconnect power before working around the door switch or control wiring.
What to check:
- Confirm door closure: Ensure the door is fully closing and not obstructed by baskets, food packages, or warped gaskets.
- Inspect door gasket: Check for tears, deformation, or hardened sections that prevent full closure. Warm the gasket gently with a hair dryer and reshape if needed.
- Locate the door switch or sensor: On many Brandt freezers, the door switch is a plunger-type switch in the frame or a magnetic reed sensor hidden in the liner.
- Test the switch: With power off, remove the switch from the cabinet. Use a multimeter to check continuity while pressing and releasing the plunger. Replace the switch if it does not change state reliably.
- Check magnet alignment (for reed sensors): Ensure the magnet in the door aligns with the sensor area when closed. If the door is sagging, adjust the hinges or add shims to restore alignment.
- Inspect wiring: Look for pinched or broken wires near the hinge area. Repair or replace the harness if damaged.
- If switch and wiring are OK: The main control board input circuit may be faulty and require replacement.