AL10
Brandt Main Control Board Fault / Power Supply Error

Freezer displays AL10; compressor and fans may stop, unit may not respond to controls

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed electronic control module, Power surge damage, Shorted component on control PCB, Loose power connector

How to Fix / Troubleshooting

Safety first: Unplug the freezer. Electronic boards contain high-voltage components; do not touch any capacitors immediately after unplugging.

Steps:

  • Check power source: Verify the outlet has correct voltage and is not controlled by a wall switch. Test with another appliance.
  • Inspect power cord: Look for cuts, burns, or kinks. Replace the cord if damaged.
  • Access main control board: On many Brandt freezers, the board is located in a rear control box or at the top behind a cover. Remove the cover screws and gently pull out the board.
  • Inspect visually: Look for burnt components, bulging capacitors, or blackened areas on the PCB. If present, the board must be replaced.
  • Check connectors: Reseat all plugs, especially the mains input and compressor/fan outputs. Ensure earth/ground connections are secure.
  • If AL10 persists after reseating: Replace the main electronic control module with the correct Brandt part number.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board (Electronic Control Module)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements