Possible Causes

Compressor not running, Failed compressor start relay, Main control board not sending power to compressor, Severe refrigerant leak or blocked capillary tube

How to Fix / Troubleshooting

Safety first: Unplug the freezer before removing rear covers. Do not attempt to open sealed copper lines.

Steps:

  • Check basic power: Confirm the outlet works and the power cord is fully inserted. Verify the thermostat or control is not set to OFF.
  • Listen for compressor: After plugging in, wait a few minutes. If the compressor is silent and not vibrating, remove the rear lower cover.
  • Inspect start relay: Remove the compressor terminal cover and check the start relay/overload for burn marks or rattling. Replace if suspect.
  • Check control board output (advanced): With appropriate safety and tools, verify that the main control board sends power to the compressor when cooling is demanded. If not, replace the board.
  • If compressor runs but no cooling: The sealed system may have a leak or blockage. This requires a certified refrigeration technician.