Bush Door Gasket Failure or Door Misalignment

Freezer door not sealing properly; visible gap or condensation around the seal.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Warped or torn door gasket, Bent door, Loose or misadjusted hinges on Bush upright freezer

How to Fix / Troubleshooting

Safety first: Unplug the freezer before adjusting hinges to avoid accidental fan or light operation.

  • Inspect gasket: Look for tears, hardened sections, or areas where the gasket does not touch the cabinet. Warm the gasket gently with a hair dryer to soften and reshape minor distortions.
  • Adjust hinges: Loosen the hinge screws slightly and lift or shift the door so it aligns evenly with the cabinet, then retighten.
  • Replace gasket: If the gasket is damaged, remove it from the door channel and fit a new door gasket designed for your Bush model. Press it firmly into the channel all around.

After adjustment or replacement, close the door on a strip of paper at several points to confirm a good seal.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Door Gasket
Check Price on Amazon