Interior Lamp or Door Switch Failure
Freezer interior light not working but cooling is normal.
Advertisements
Possible Causes
Blown LED lamp module or bulb, Faulty door switch, Loose lamp wiring connection
How to Fix / Troubleshooting
Safety first: Unplug the freezer before replacing any lamp or switch.
- Check lamp type: Many Bush freezers use an LED lamp module; some older models use a small bulb.
- Test door switch: Press the door switch manually. If the light flickers or never comes on, the switch may be faulty. Replace the door switch if it has no continuity when pressed.
- Replace lamp: Remove the lamp cover (usually clipped or screwed). Replace the LED lamp module or bulb with a Bush-compatible part of the same rating.
After replacement, restore power and confirm the light operates when the door is opened.