AL
Café
General Alarm Condition (Temperature or Door)
Freezer display shows AL and an audible alarm sounds
Advertisements
Possible Causes
Door left open, High temperature condition, Failed door switch, Faulty temperature sensor
How to Fix / Troubleshooting
Safety first: You can troubleshoot with power on; avoid contact with live terminals.
- Silence alarm: Press the alarm reset or any control button to silence the alarm temporarily.
- Check door and gasket: Ensure the door is fully closed and the gasket is sealing. Correct any obstructions or misalignment.
- Verify temperature: Use a thermometer to check actual freezer temperature. If high, follow high temperature troubleshooting (clean coils, check fan, etc.).
- Test door switch: Press the door switch manually; the interior light should turn off. Replace the switch if it does not operate correctly.
- Sensor check: If the alarm persists with normal temperature and a good door switch, test the freezer thermistor and replace if faulty.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements