Café Continuous Run Condition

Freezer runs continuously and rarely shuts off, even when very cold

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Thermistor reading too warm, Door gasket leak, Control board relay stuck closed, Ambient temperature very high

How to Fix / Troubleshooting

Safety first: Unplug the freezer before testing sensors or boards.

  • Check actual temperature: Use a thermometer to confirm interior temperature. If it is at or below the setpoint, continuous running indicates a control issue.
  • Inspect gasket and door closure: Repair any leaks that cause warm air infiltration.
  • Test thermistor: Replace if it reads incorrectly and always indicates a warm condition.
  • Control board relay: If the compressor remains on even when the control should be satisfied, the main control board relay may be stuck and the board should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board