E17
Candy
Door Switch Logic or Light Circuit Fault
Freezer shows E17 and may not recognize door open/close state correctly; interior light may stay on.
Advertisements
Possible Causes
Failed door switch, Shorted light circuit, Stuck relay controlling light, Damaged wiring in door area
How to Fix / Troubleshooting
Safety first: Unplug the freezer before working on the door switch or light wiring.
- Test door switch: Locate the door switch in the frame. Remove it and test continuity with a multimeter while pressing and releasing it. Replace if it does not change state.
- Inspect light module: Remove the interior light cover and check for signs of overheating or shorting.
- Check wiring: Follow the wires from the switch and light back to the control board, looking for pinched or damaged insulation.
- Replace faulty parts: Install a new Candy-compatible door switch or LED light module as needed.
- Verify operation: After reassembly, plug in the freezer and confirm that the light turns off when the door is closed and that E17 is cleared.
Warning: Do not bypass the door switch; it may affect defrost and alarm logic.
Advertisements
Repair Difficulty
Easy
2/5