Caple No Power / Main Fuse or PCB Power Supply Failure

Display completely dead; freezer not running at all

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse on main PCB, Faulty mains cable or plug, Failed PCB power supply section, Tripped household circuit breaker

How to Fix / Troubleshooting

Safety: Always unplug the freezer before inspecting the plug or PCB. If a breaker trips repeatedly, do not reset continuously.

Steps to diagnose no‑power condition:

  • 1. Check outlet and breaker: Test the socket with another appliance. Reset any tripped breaker once; if it trips again when the freezer is plugged in, stop and call an electrician or technician.
  • 2. Inspect mains cable and plug: Look for cuts, burns, or loose pins. Replace the plug or cable if damaged.
  • 3. Access main PCB: Remove the PCB cover and look for an onboard fuse. Test continuity and replace with the exact same rating if blown.
  • 4. Inspect PCB: Look for burnt components in the power supply area. If present, replace the entire PCB.

Warning: Do not bypass fuses or use oversized replacements; this is a fire hazard.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.