Caple
High Condenser Temperature / Poor Ventilation
Freezer cabinet sides feel very hot to the touch
Advertisements
Possible Causes
Insufficient clearance around freezer, Condenser coils heavily dust‑clogged, Ambient temperature too high, Internal condenser fan (if fitted) not running
How to Fix / Troubleshooting
Safety: Unplug before cleaning or accessing rear components.
Steps to reduce cabinet temperature:
- 1. Improve ventilation: Move the freezer away from walls and ensure vents are not blocked.
- 2. Clean condenser: Vacuum and brush dust from coils and grilles.
- 3. Check condenser fan (if present): Some built‑in Caple models use a fan near the condenser. Ensure it runs when the compressor is on; replace if failed.
- 4. Verify ambient conditions: Avoid installing the freezer in rooms above the manufacturer’s recommended temperature range.
Note: Slight warmth on the sides is normal, but excessive heat indicates a ventilation or load issue.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.